Customization: | Available |
---|---|
Usage: | Data Center Enterprise, Communication Transmision, Data Center Enterprise, Communication Transmision |
Support Network: | Ethernet, Ethernet |
Still deciding? Get samples of US$ 3/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Parameter | Symbol | Min | Type | Max | Units |
Maximum Supply Voltage | Vcc | -0.5 | 4.0 | V | |
Storage Temperature | TS | -40 | 85 | °C |
Parameter | Symbol | Min | Type | Max | Units | |
Operating Case Temperature | Tc | UNSFP-10G-T | 0 | 70 | °C | |
Supply Voltage | Vcc | 3.14 | 3.3 | 3.46 | V | |
Product Certificate | Certificate Number | Applicable Standard |
TUV | R50135086 | EN 60950-1:2006+A11+A1+A12+A2 |
EN 60825-1:2014 | ||
EN 60825-2:2004+A1+A2 | ||
UL | E317337 | UL 60950-1 |
CSA C22.2 No. 60950-1-07 | ||
EMC CE | AE 50285865 0001 | EN 55022:2010 |
EN 55024:2010 | ||
FCC | WTF14F0514417E | 47 CFR PART 15 OCT., 2013 |
FDA | / | CDRH 1040.10 |
ROHS | / | 2011/65/EU |
Parameter | Symbol | Min | Typ | Max | Units | Notes/Conditions |
+3.3 Volt Electrical Power Interface | ||||||
Supply Current | Icc | 800 | mA | |||
Input Voltage | Vcc | 3.13 | 3.3 | 3.47 | V | |
Low-Speed Signals, Electronic Characteristics | ||||||
SFP Output LOW | VOL | 0 | 0.5 | V | 4.7k to 10k pull-up to host_Vcc, measured at host side of connector |
|
SFP Output HIGH | OH |
host_ Vcc - 0.5 |
host_ Vcc + 0.3 |
V | 4.7k to 10k pull-up to host_Vcc, measured at host side of connector |
|
SFP Input LOW | VIL | 0 | 0.8 | V | 4.7k to 10k pull-up to Vcc, measured at SFP side of connector |
|
SFP Input HIGH | VIH | 2 | Vcc + 0.3 | V | 4.7k to 10k pull-up to Vcc, measured at SFP side of connector |
|
High-Speed Electrical Interface, Transmission Line-SFP | ||||||
Tx Output impedance | Zout,TX | 100 | Ohm | Differential, for all frequencies between 1MHz and 125MHz |
||
Rx Input Impedance | Zin,RX | 100 | Ohm | Differential, for all frequencies between 1MHz and 125MHz |
||
High-Speed Electrical Interface, Host-SFP | ||||||
Single ended data input swing |
Vin | 250 | 1200 | mV | Single ended | |
Single ended data output swing |
Vout | 350 | 800 | mV | Single ended | |
Rise/Fall Time | Tr,Tf | 20 | psec | 20%-80% | ||
Tx Input Impedance |
Zin | 50 | Ohm | Single ended | ||
Rx Output Impedance |
Zout | 50 | Ohm | Single ended |
Pin No. | Name | Function | Plug Seq. | Notes |
1 | VeeT | Transmitter Ground | 1 | |
2 | TX Fault | Transmitter Fault Indication | 3 | Not used |
3 | TX Disable | Transmitter Disable | 3 | 1 |
4 | MOD-DEF2 | Module Definition 2 | 3 | 2 |
5 | MOD-DEF1 | Module Definition 1 | 3 | 2 |
6 | MOD-DEF0 | Module Definition 0 | 3 | 2 |
7 | RS0 | No Connection required | 3 | |
8 | LOS | Loss of Signal | 3 | RX_LOSS |
9 | RS1 | No Connection required | 1 | |
10 | VeeR | Receiver Ground | 1 | |
11 | VeeR | Receiver Ground | 1 | |
12 | RD- | Inv. Received Data Out | 3 | |
13 | RD+ | Received Data Out | 3 | |
14 | VeeR | Receiver Ground | 1 | |
15 | VccR | Receiver Power | 2 | |
16 | VccT | Transmitter Power | 2 | |
17 | VeeT | Transmitter Ground | 1 | |
18 | TD+ | Transmit Data In | 3 | |
19 | TD- | Inv. Transmit Data In | 3 | |
20 | VeeT | Transmitter Ground | 1 |
Addr. | Size (Bytes) |
Name of Field | Hex | Description | |||
BASE ID FIELDS | |||||||
0 | 1 | Identifier | 03 | SFP | |||
1 | 1 | Ext. Identifier | 04 | SFP function is defined by serial ID only |
|||
2 | 1 | Connector | 07 | -LC | |||
3-10 | 8 | Transceiver | 10 00 00 00 00 00 00 00 |
Transmitter Code | |||
11 | 1 | Encoding | 06 | 64B/66B | |||
12 | 1 | BR, Nominal | 67 | 10.3G | |||
13 | 1 | Reserved | 00 | - | |||
14 | 1 | Length (9µm)km | 00 | ||||
15 | 1 | Length(9µm)100m | 00 | ||||
16 | 1 | Length (50µm) 10m | 08 | 80m | |||
17 | 1 | Length(62.5µm)10m | 02 | 20m | |||
18 | 1 | Length (Copper) | 00 | ||||
19 | 1 | Reserved | 1E | 300m | |||
20-35 | 16 | Vendor name | XX XX XX XX XX XX XX XX(note2)20 20 20 20 20 20 20 20 |
Vendor name (ASCII) | |||
36 | 1 | Reserved | 00 | - | |||
37-39 | 3 | Vendor OUI | XX XX XX(note2) | - | |||
40-55 | 16 | Vendor PN | XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX(note2) |
Transceiver part number | |||
56-59 | 4 | Vendor rev | XX XX XX XX(note2) | - | |||
60-61 | 2 | Wavelength | 03 52 | -850nm | |||
62 | 1 | Reserved | 00 | - | |||
63 | 1 | CC_BASE | Check Sum (Variable) |
Check code for Base ID Fields | |||
EXTENDED ID FIELDS | |||||||
64-65 | 2 | Options | 00 1A | TX_DISABLE, TX_FAULT and Loss of Signal implemented. |
|||
66 | 1 | BR, max | 00 | ||||
67 | 1 | BR, min | 00 | ||||
68-83 | 16 | Vendor SN | XX XX XX XX XX XX XX XX 20 20 20 20 20 20 20 20(note2) |
Serial Number of transceiver (ASCII). For example "B000822". | |||
84-91 | 8 | Date code | XX XX XX XX XX XX XX XX(note2) |
Manufactory date code. For example "080405". |
|||
92 | 1 | Diagnostic Monitoring Type |
XX(note2) | Digital diagnostic monitoring implemented |
|||
93 | 1 | Enhanced Options | XX(note2) | Optional flags | |||
94 | 1 | SFF_8472 Compliance |
XX(note2) | 01 for diagnostics (Rev9.3 SFF-8472). |
|||
95 | 1 | CC_EXT | Check Sum | Check sum for Extended ID | |||
(Variable) | Field. | ||||||
VENDOR SPECIFIC ID FIELDS | |||||||
96-127 | 32 | Vendor Specific | Read only | Depends on customer information |
|||
128-255 | 128 | Reserved | Read only | - | |||
Part No. | Data Rate | Media type | Distance | Connector | Temperature |
UNSFP-10G-T* Note3 | 10G | CAT6A/CAT7 | 30m | RJ45 | Standard |