Parameter | Symbol | Min. | Typ. | Max. | Unit | Note |
Storage Temperature | Ts | -40 | - | 85 | ºC | |
Relative Humidity | RH | 5 | - | 95 | % | |
Power Supply Voltage | VCC | -0.3 | - | 4 | V | |
Signal Input Voltage | Vcc-0.3 | - | Vcc+0.3 | V |
Parameter | Symbol | Min. | Typ. | Max. | Unit | Note |
Case Operating Temperature | Tcase | 0 | - | 70 | ºC | Without air flow |
Power Supply Voltage | VCC | 3.14 | 3.3 | 3.47 | V | |
Power Supply Current | ICC | - | 450 | mA | ||
Data Rate | BR | 10.3125 | Gbps | |||
Transmission Distance | TD | - | 10 | km | ||
Coupled fiber | Single mode fiber | 9/125um SMF |
Parameter | Symbol | Min | Typ | Max | Unit | NOTE |
Transmitter | ||||||
Output Opt. Power | POUT | -6 | -0.5 | dBm | 1 | |
Optical Wavelength | λ | 1260 | 1310 | 1355 | nm | |
Spectral Width (-20dB) | σ | 1 | nm | |||
Optical Extinction Ratio | ER | 3.5 | dB | |||
Output Eye Mask | Compliant with IEEE 802.3ae | |||||
Receiver | ||||||
Rx Sensitivity | RSENS | -14.4 | dBm | 2 | ||
Input Saturation Power (Overload) | Psat | 0.5 | dBm | |||
Wavelength Range | λC | 1270 | 1610 | nm | ||
LOS De -Assert | LOSD | -17 | dBm | |||
LOS Assert | LOSA | -30 | dBm | |||
LOS Hysteresis | 0.5 | 1.0 | dB |
Parameter | Symbol | Min | Typ | Max | Unit | NOTE |
Supply Voltage | Vcc | 3.14 | 3.3 | 3.46 | V | |
Supply Current | Icc | 450 | mA | |||
Transmitter | ||||||
Input differential impedance | Rin | 100 | Ω | 1 | ||
Single ended data input swing | Vin,pp | 180 | 700 | mV | ||
Transmit Disable Voltage | VD | Vcc-1.3 | Vcc | V | ||
Transmit Enable Voltage | VEN | Vee | Vee+ 0.8 | V | 2 | |
Transmit Disable Assert Time | 10 | us | ||||
Receiver | ||||||
Differential data output swing | Vout,pp | 300 | 850 | mV | 3 | |
Data output rise time | tr | 28 | ps | 4 | ||
Data output fall time | tf | 28 | ps | 4 | ||
LOS Fault | VLOS fault | Vcc-1.3 | VccHOST | V | 5 | |
LOS Normal | VLOS norm | Vee | Vee+0.8 | V | 5 | |
Power Supply Rejection | PSR | 100 | mVpp | 6 |
Pin | Symbol | Name/Description | NOTE |
1 | VEET | Transmitter Ground (Common with Receiver Ground) | 1 |
2 | TFAULT | Transmitter Fault. | 2 |
3 | TDIS | Transmitter Disable. Laser output disabled on high or open. | 3 |
4 | SDA | 2-wire Serial Interface Data Line | 4 |
5 | SCL | 2-wire Serial Interface Clock Line | 4 |
6 | MOD_ABS | Module Absent. Grounded within the module | 4 |
7 | RS0 | Rate Select 0 | 5 |
8 | LOS | Loss of Signal indication. Logic 0 indicates normal operation. | 6 |
9 | RS1 | No connection required | 1 |
10 | VEER | Receiver Ground (Common with Transmitter Ground) | 1 |
11 | VEER | Receiver Ground (Common with Transmitter Ground) | 1 |
12 | RD- | Receiver Inverted DATA out. AC Coupled | |
13 | RD+ | Receiver Non-inverted DATA out. AC Coupled | |
14 | VEER | Receiver Ground (Common with Transmitter Ground) | 1 |
15 | VCCR | Receiver Power Supply | |
16 | VCCT | Transmitter Power Supply | |
17 | VEET | Transmitter Ground (Common with Receiver Ground) | 1 |
18 | TD+ | Transmitter Non-Inverted DATA in. AC Coupled. | |
19 | TD- | Transmitter Inverted DATA in. AC Coupled. | |
20 | VEET | Transmitter Ground (Common with Receiver Ground) | 1 |