Pin | Symbol | Description | Notes |
1 | GND | Ground | 1 |
2 | Tx2n | Transmitter Inverted Data Input | |
3 | Tx2p | Transmitter Non-Inverted Data Input | |
4 | GND | Ground | 1 |
5 | Tx4n | Transmitter Inverted Data Input | |
6 | Tx4p | Transmitter Non-Inverted Data Input | |
7 | GND | Ground | 1 |
8 | ModSelL | Module Select | |
9 | ResetL | Module Reset | |
10 | Vcc Rx | +3.3 V Power Supply Receiver | |
11 | SCL | 2-wire Serial Interface Clock | |
12 | SDA | 2-wire Serial Interface Data | |
13 | GND | Ground | 1 |
14 | Rx3p | Receiver Non-Inverted Data Output | |
15 | Rx3n | Receiver Inverted Data Output | |
16 | GND | Ground | 1 |
17 | Rx1p | Receiver Non-Inverted Data Output | |
18 | Rx1n | Receiver Inverted Data Output | |
19 | GND | Ground | 1 |
20 | GND | Ground | 1 |
21 | Rx2n | Receiver Inverted Data Output | |
22 | Rx2p | Receiver Non-Inverted Data Output | |
23 | GND | Ground | 1 |
24 | Rx4n | Receiver Inverted Data Output | |
25 | Rx4p | Receiver Non-Inverted Data Output | |
26 | GND | Ground | 1 |
27 | ModPrsL | Module Present | |
28 | IntL | Interrupt | |
29 | Vcc Tx | +3.3 V Power Supply Transmitter | |
30 | Vcc1 | +3.3 V Power Supply | |
31 | LPMode | Low Power Mode | |
32 | GND | Ground | 1 |
33 | Tx3p | Transmitter Non-Inverted Data Input | |
34 | Tx3n | Transmitter Inverted Data Input | |
35 | GND | Ground | 1 |
36 | Tx1p | Transmitter Non-Inverted Data Input | |
37 | Tx1n | Transmitter Inverted Data Input | |
38 | GND | Ground | 1 |
Parameter | Symbol | Min | Typ | Max | Unit | Notes |
Maximum supply voltage | Vcc | -0.3 | 3.3 | 3.6 | V | |
Storage temperature | Ts | -40 | +85 | °C | ||
Relative humidity | RH | 5 | 85 | % | Non-condensing | |
Damage threshold, each lane | THd | 5 | dBm |
Parameter | Symbol | Min | Typ | Max | Unit |
Supply voltage | Vcc | 3.135 | 3.3 | 3.465 | V |
Case temperature | Top | 0 | +70 | °C | |
Data rate, each lane | 25.78125 | Gbps | |||
Data rate accuracy | -100 | 100 | ppm | ||
Link distance with OM3/OM4 | 70/100 | m |
Parameters | Min | Typ | Max | Unit |
Transmitter | ||||
Data rate, each lane | 53.125 | Gbps | ||
Signaling speed accuracy | -100 | 100 | ppm | |
Wavelengths 1 | 844 | 863 | nm | |
Wavelengths 2 | 900 | 918 | Nm | |
RMS spectral width | 0.6@850nm 0.65@908nm |
nm | ||
Average launch power, each lane | -4.4 | +4 | dBm | |
Optical modulation amplitude | -3.2 | +3 | dBm | |
Transmitter and dispersion eye closure for PAM4 (TDECQ) | 4.5 | dB | ||
Launch power in OMAouter minus TDECQ | -5.6 | dBm | ||
Average launch power of OFF transmitter | -30 | dB | ||
Extinction ratio (ER) | 3 | dB | ||
RIN12 OMA | -128 | dB/Hz | ||
Optical return loss tolerance | 12 | dB | ||
Encircled flux | ≥ 86% @ 19 μm, ≤ 30%@ 4.5 μm | |||
Receiver | ||||
Data rate, each lane | 53.125 | Gbps | ||
Signaling speed accuracy | -100 | 100 | ppm | |
Wavelengths 1 | 844 | 863 | nm | |
Wavelengths 2 | 900 | 918 | nm | |
Average receive power | -8.2 | +4 | dBm | |
Optical modulation amplitude receive | - | +3 | dBm | |
Damage threshold | +5 | dBm | ||
Saturation power | 3.5 | dBm | ||
Receiver reflectance | -12 | dB | ||
Receiver sensitivity | Max (-6.6, SECQ - 8) @5E-5 | dBm | ||
Stress sensitivity OMA | -3.5 | dBm | ||
Conditions of stressed receiver sensitivity test | ||||
Stressed eye closure for PAM4 (SECQ) | 4.5 | dB | ||
OMAouter of each aggressor lane | +3 | dBm | ||
No-power monitor RX | -40 | dBm | ||
LOS assert (OMA) | -30 | dBm | ||
LOS de-assert (OMA) | -5.9 | dBm | ||
LOS hysteresis | 0.5 | dBm |
Parameter | Symbol | Min | Typ | Max | Unit |
Power dissipation | 4 | W | |||
Supply current | Icc | 1.276 | A | ||
Transmitter | |||||
Differential input voltage swing | Vpp | 35 | 900 | mV | |
Differential input impedance | Zin | 90 | 100 | 110 | Ω |
Receiver | |||||
Differential output voltage swing | Vpp | 900 | mV | ||
Differential input impedance | Zout | 90 | 100 | 110 | Ω |
Data Address | Name | Description | Value (Hex) | Read/Write |
0 | Identifier | Identifier | Read-Only | |
1 | Status | Revision Compliance | Read-Only | |
2 | Status | Read-Only | ||
3 | Interrupt Flags | L-Tx/RX LOS, channel 1~4 | Read-Only | |
4 | L-Tx/RX Adapt EQ Fault, channel 1~4 L-TX Fault, channel 1~4 | Read-Only | ||
5 | L-Tx/RX LOL, channel 1~4 | Read-Only | ||
6 | L-Temp High/Low Alarm/Warning Initialization complete flag | Read-Only | ||
7 | L-VCC High/Low Alarm/Warning | Read-Only | ||
8 | Vendor Specific | Read-Only | ||
9 | L-Rx Power High/Low Alarm/Warning, channel 1~2 | Read-Only | ||
10 | L-RxPower High/Low Alarm/Warning, channel 3~4 | Read-Only | ||
11 | L-Tx Bias High/Low Alarm/Warning, channel 1~2 | Read-Only | ||
12 | L-Tx Bias High/Low Alarm/Warning, channel 3~4 | Read-Only | ||
13 | L-Tx Power High/Low Alarm/Warning, channel 1~2 | Read-Only | ||
14 | L-Tx Power High/Low Alarm/Warning, channel 3~4 | Read-Only | ||
15-18 | Reserved | Read-Only | ||
19-21 | Vendor Specific | Read-Only | ||
22 | Free Side Device Monitors | Internally measured temperature (MSB) | Read-Only | |
23 | Internally measured temperature (LSB) | Read-Only | ||
24 | Reserved | Read-Only | ||
25 | Read-Only | |||
26 | Internally measured supply voltage (MSB) | Read-Only | ||
27 | Internally measured supply voltage (LSB) | Read-Only | ||
28-29 | Reserved | Read-Only | ||
30-33 | Vendor Specific | Read-Only | ||
34 | Channel Monitors | Internally measured RX input power, channel 1 (MSB) | Read-Only | |
35 | Internally measured RX input power, channel 1 (LSB) | Read-Only | ||
36 | Channel Monitors | Internally measured RX input power, channel 2 (MSB) | Read-Only | |
37 | Internally measured RX input power, channel 2 (LSB) | Read-Only | ||
38 | Internally measured RX input power, channel 3 (MSB) | Read-Only | ||
39 | Internally measured RX input power, channel 3 (LSB) | Read-Only | ||
40 | Internally measured RX input power, channel 4 (MSB) | Read-Only | ||
41 | Internally measured RX input power, channel 4 (LSB) | Read-Only | ||
42 | Internally measured TX bias, channel 1 (MSB) | Read-Only | ||
43 | Internally measured TX bias, channel 1 (LSB) | Read-Only | ||
44 | Internally measured TX bias, channel 2 (MSB) | Read-Only | ||
45 | Internally measured TX bias, channel 2 (LSB) | Read-Only | ||
46 | Internally measured TX bias, channel 3 (MSB) | Read-Only | ||
47 | Internally measured TX bias, channel 3 (LSB) | Read-Only | ||
48 | Internally measured TX bias, channel 4 (MSB) | Read-Only | ||
49 | Internally measured TX bias, channel 4 (LSB) | Read-Only | ||
50 | Internally measured TX Power, channel 1 (MSB) | Read-Only | ||
51 | Internally measured TX Power, channel 1 (LSB) | Read-Only | ||
52 | Internally measured TX Power, channel 2 (MSB) | Read-Only | ||
53 | Internally measured TX Power, channel 2 (LSB) | Read-Only | ||
54 | Internally measured TX Power, channel 3 (MSB) | Read-Only | ||
55 | Internally measured TX Power, channel 3 (LSB) | Read-Only | ||
56 | Channel Monitors | Internally measured TX Power, channel 4 (MSB) | Read-Only | |
57 | Internally measured TX Power, channel 4 (LSB) | Read-Only | ||
58-73 | Reserved channel monitor | Read-Only | ||
74-81 | Vendor Specific | Read-Only | ||
82-85 | Reserved | Read-Only | ||
86 | Control | Tx Disable, channel 1~4 | Read/Write | |
87 | Rx_Rate_select, channel 1~4 | Read/Write | ||
88 | Tx_Rate_select, channel 1~4 | Read/Write | ||
89 | Rx4_Application_Select, Rx Channel 4 | Read/Write | ||
90 | Rx3_Application_Select, Rx Channel 3 | Read/Write | ||
91 | Rx2_Application_Select, Rx Channel 2 | Read/Write | ||
92 | Rx1_Application_Select, Rx Channel 1 | Read/Write | ||
93 | Reserved High Power Class Enable Power set Power override | Read/Write | ||
94 | Tx4_Application_Select, Rx Channel 4 | Read/Write | ||
95 | Tx3_Application_Select, Rx Channel 3 | Read/Write | ||
96 | Tx2_Application_Select, Rx Channel 2 | Read/Write | ||
97 | Tx1_Application_Select, Rx Channel 1 | Read/Write | ||
98 | Tx/Rx_CDR_control, channel 1~4 | Read/Write | ||
99 | Reserved | Read/Write | ||
100 | Module and Channel Masks | Masking Bit for TX/RX LOS indicator, channel 1~4 | Read/Write | |
101 | Masking Bit for TX, Adaptive EQ fault indicator, channel 1~4 Masking Bit for TX Transmitter/Laser indicator, channel 1~4 | Read/Write | ||
102 | Masking Bit for TX/RX CDR Loss of Lock indicator, channel 1~4 | Read/Write | ||
103 | Masking Bit for Temperature alarm/warning | Read/Write | ||
104 | Masking Bit for Vcc alarm/warning | Read/Write | ||
105-106 | Vendor Specific | Read/Write | ||
107 | Reserved | Max Power Consumption | Read/Write | |
108 | Free Side Device Properties | Propagation Delay MSB | Read-Only | |
109 | Propagation Delay LSB | Read-Only | ||
110 | Free Side Device Properties | Advanced Low Power Mode Far Side Managed Min Operating Voltage | Read-Only | |
111 | Assigned for use by PCI Express | Read-Only | ||
112 | Read/Write | |||
113 | Free Side Device Properties | Far-End Implementation Near-End Implementation |
Read/Write | |
114 | Tx_TurnOn MaxDuration DatapathInit MaxDuration |
|||
115 | ModSelL wait time exponent ModSelL wait time mantissa |
|||
116 | Secondary Extended Spec Compliance | |||
117-118 | Reserved | |||
119-122 | Password Change Entry Area | Read/Write | ||
123-126 | Password Entry Area | Read/Write | ||
127 | Page Select Byte | Page Select | Read/Write | |
128 | Identifier | Identifier Type of serial Module | Read-Only | |
129 | Ext. Identifier | Extended Identifier of Serial Module | Read-Only | |
130 | Connector | Code for connector type | Read-Only | |
131-138 | Specification compliance | Code for electronic compatibility or optical compatibility | Read-Only | |
139 | Encoding | Code for serial encoding algorithm | Read-Only | |
140 | BR, nominal | Nominal bit rate, units of 100 MBits/s | Read-Only | |
141 | Extended Rate Select Compliance | Tags for extended rate select compliance | Read-Only | |
142 | Length (SMF) | Link length supported for SMF fiber in km (note 1) | Read-Only | |
143 | Length (OM3 50 μm) | Link length supported for EBW 50/125 μm fiber (OM3), units of 2 m | Read-Only | |
144 | Length (OM2 50 μm) | Link length supported for 50/125 μm fiber (OM2), units of 1 m | Read-Only | |
145 | Length (OM1 62.5 μm) | Link length supported for 62.5/125 μm fiber (OM1), units of 1 m | Read-Only | |
146 | Length (Copper) | Link length of copper or active cable, units of 1 m, Link length supported for 50/125 μm fiber (OM4), units of 2 m | Read-Only | |
147 | Device technology | Device technology | Read-Only | |
148-163 | Vendor name | QSFP28 vendor name (ASCII) | Read-Only | |
164 | Extended Module | Extended Module codes for InfiniBand | Read-Only | |
165-167 | Vendor OUI | QSFP28 vendor IEEE company ID | Read-Only | |
168-183 | Vendor PN | Part number provided by QSFP28 vendor (ASCII) | Read-Only | |
184 | Vendor rev | Revision level for part number provided by vendor (ASCII) | Read-Only | |
185 | Read-Only | |||
186 | Wave length or Copper cable Attenuation | Nominal laser wavelength (wavelength=value/20 in nm) or copper cable attenuation in dB at 2.5 GHz (Byte 186) and 5.0 GHz (Byte 187) | Read-Only | |
187 | Read-Only | |||
188 | Wavelength tolerance | Guaranteed range of laser wavelength (+/- value) from nominal wavelength. (wavelength Tol.=value/200 in nm) | Read-Only | |
189 | Read-Only | |||
190 | Max case temp. | Maximum case temperature in degrees C | Read-Only | |
191 | CC_BASE | Check code for base ID fields (Bytes 128-190) | Read-Only | |
192 | Link codes | Extended Specification Compliance Codes | Read-Only | |
193 | Options | Rate Select, TX Disable, TX Fault, LOS, Warning indicators for: Temperature, VCC, RX power, TX Bias | Read-Only | |
194 | Read-Only | |||
195 | Read-Only | |||
196-211 | Vendor SN | Serial number provided by vendor (ASCII) | Read-Only | |
212-219 | Date Code | Vendor's manufacturing date code | Read-Only | |
220 | Diagnostic Monitoring Type | Indicates which types of diagnostic monitoring are implemented (if any) in the Module. Bit 1,0 Reserved | * | Read-Only |
221 | Enhanced Options | Indicates which optional enhanced features are implemented in the Module. | * | Read-Only |
222 | BR, nominal | Nominal bit rate per channel, units of 250 Mbps. Complements Byte 140 | * | Read-Only |
223 | CC_EXT | Check code for the Extended ID Fields (Bytes 192-222) | * | Read-Only |
224-255 | Vendor Specific EEPROM | Vendor Specific ID | * | Read-Only |
Performance Item | Data Address | Monitor Error | |
Alarm & Warning | Monitor | ||
Module temperature | 6 | 22-23 | ≤ ±3°C |
Module voltage | 7 | 26-27 | ≤ ±3% |
Bias current | 11-12 | 42-49 | ≤ ±10% |
Transmitter optical power | 13-14 | 50-57 | ≤ ±3 dB |
Receiver optical power | 9-10 | 34-41 | ≤ ±3 dB |
Feature | Category | Standard | Performance |
Safety | NRTL | UL 62368-1 CAN/CSA C22.2 No. 62368-1 |
NRTL recognized component for US and CAN |
TUV | EN 62368-1 EN 60825-1:2014+A11:2021 EN 60825-2 |
TUV certificate | |
FDA | U.S. 21 CFR 1040.10 & 1040.11, Notice 56 | FDA/CDRH certified with accession number according to Laser Notice 56 | |
Electromagnetic Compatibility | Radiated emissions |
EN 55032 CISPR 32 ICES-003 VCCI-CISPR 32 AS/NZS CISPR 32 |
Class B digital device with a minimum -6 dB margin to the limit when tested with a metal enclosure. Final margin may vary depending on system application, good system EMI design practice, ie: suitable metal enclosure and well-bonding, is required to achieve Class B margins at the system level. Tested frequency range: 30 MHz to 40 GHz or 5th harmonic (5 times the highest frequency), whichever is less. |
ESD | EN 55035 CISPR 35 |
Withstands discharges of ± 8 kV contact, ±15 kV air. | |
Radiated immunity |
EN 55035 CISPR 35 |
Field strength of 10 V/m from 80 MHz to 6 GHz. | |
Restriction of Hazardous Substances | RoHS | EN IEC 63000:2018 & BS EN IEC 63000:2018 |
Parameter | Threshold value | Notes |
ESD of high-speed pins | 1 kV | Human body model |
ESD of low-speed pins | 2 kV | Human body model |
Air discharge during operation | 15 kV | |
Direct contact discharges to the case | 8 kV |