Qsfp28 100g Bidi Transceiver Module for 70 M/100m Om3/Om4 mm Fiber

Product Details
Customization: Available
Usage: Workstation, Server
Type: Wireless
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
10000000 RMB
Plant Area
>2000 square meters
  • Qsfp28 100g Bidi Transceiver Module for 70 M/100m Om3/Om4 mm Fiber
  • Qsfp28 100g Bidi Transceiver Module for 70 M/100m Om3/Om4 mm Fiber
  • Qsfp28 100g Bidi Transceiver Module for 70 M/100m Om3/Om4 mm Fiber
  • Qsfp28 100g Bidi Transceiver Module for 70 M/100m Om3/Om4 mm Fiber
  • Qsfp28 100g Bidi Transceiver Module for 70 M/100m Om3/Om4 mm Fiber
  • Qsfp28 100g Bidi Transceiver Module for 70 M/100m Om3/Om4 mm Fiber
Find Similar Products

Basic Info.

Model NO.
LAQ28-SR2
Support Network
Ethernet
Information content
Data
Certification
CE, ISO, RoHS
Condition
New
Transport Package
Blister Pack
Trademark
Link-all
Origin
China
HS Code
8517706000
Production Capacity
100, 000 Per Year

Packaging & Delivery

Package Size
10.00cm * 10.00cm * 10.00cm
Package Gross Weight
1.000kg

Product Description

100Gbps QSFP28 BIDI SR Transceiver 100M/OM4(FEC) DDM
LAQ28-SR

Product Features
  • QSFP28 MSA compliant
  • IEEE 802.3 bm-2015 compliant                                                                                                      
  • 2 BiDi lanes MUX/DEMUX design
  • 4 x 25.78125G electrical interface (CAUI-4)
  • Maximum power consumption 4 W
  • LC duplex receptacle
  • 103.125 Gbps aggregate bit rate
  • Up to 70 m/100 m transmission on OM3/OM4 fiber with FEC
  • Operating case temperature: 0°C to +70°C
  • Single 3.3 V power supply
  • I2C digital management interface
  • RoHS 2 compliant
Applications
  • 100GE Ethernet
  • Data Center Interconnect
  • Enterprise Networking
Pin Descriptions
Pin Symbol Description Notes
1 GND Ground 1
2 Tx2n Transmitter Inverted Data Input  
3 Tx2p Transmitter Non-Inverted Data Input  
4 GND Ground 1
5 Tx4n Transmitter Inverted Data Input  
6 Tx4p Transmitter Non-Inverted Data Input  
7 GND Ground 1
8 ModSelL Module Select  
9 ResetL Module Reset                                                                             
10 Vcc Rx +3.3 V Power Supply Receiver  
11 SCL 2-wire Serial Interface Clock  
12 SDA 2-wire Serial Interface Data  
13 GND Ground 1
14 Rx3p Receiver Non-Inverted Data Output  
15 Rx3n Receiver Inverted Data Output  
16 GND Ground 1
17 Rx1p Receiver Non-Inverted Data Output  
18 Rx1n Receiver Inverted Data Output  
19 GND Ground 1
20 GND Ground 1
21 Rx2n Receiver Inverted Data Output  
22 Rx2p Receiver Non-Inverted Data Output  
23 GND Ground 1
24 Rx4n Receiver Inverted Data Output  
25 Rx4p Receiver Non-Inverted Data Output  
26 GND Ground 1
27 ModPrsL Module Present  
28 IntL Interrupt  
29 Vcc Tx +3.3 V Power Supply Transmitter  
30 Vcc1 +3.3 V Power Supply  
31 LPMode Low Power Mode  
32 GND Ground 1
33 Tx3p Transmitter Non-Inverted Data Input  
34 Tx3n Transmitter Inverted Data Input  
35 GND Ground 1
36 Tx1p Transmitter Non-Inverted Data Input  
37 Tx1n Transmitter Inverted Data Input  
38 GND Ground 1
Notes: Circuit ground is internally isolated from chassis ground.

Absolute Maximum Ratings

It has to be noted that the operation in excess of any individual absolute maximum ratings might cause permanent damage to this module.
Parameter Symbol Min Typ Max Unit Notes
Maximum supply voltage Vcc -0.3 3.3 3.6 V  
Storage temperature Ts -40   +85 °C  
Relative humidity RH 5   85 % Non-condensing
Damage threshold, each lane THd 5     dBm  

Operating Environments
Electrical and optical characteristics below are defined under this operating environment, unless otherwise specified.
Parameter Symbol Min Typ Max Unit
Supply voltage Vcc 3.135 3.3 3.465 V
Case temperature Top 0   +70 °C
Data rate, each lane     25.78125   Gbps
Data rate accuracy   -100   100 ppm
Link distance with OM3/OM4       70/100 m
Optical Characteristics
Parameters Min Typ Max Unit
Transmitter
Data rate, each lane   53.125   Gbps
Signaling speed accuracy -100   100 ppm
Wavelengths 1 844   863 nm
Wavelengths 2 900   918 Nm
RMS spectral width     0.6@850nm
0.65@908nm
nm
Average launch power, each lane -4.4   +4 dBm
Optical modulation amplitude -3.2   +3 dBm
Transmitter and dispersion eye closure for PAM4 (TDECQ)     4.5 dB
Launch power in OMAouter minus TDECQ -5.6     dBm
Average launch power of OFF transmitter     -30 dB
Extinction ratio (ER) 3     dB
RIN12 OMA     -128 dB/Hz
Optical return loss tolerance     12 dB
Encircled flux ≥ 86% @ 19 μm, ≤ 30%@ 4.5 μm  
Receiver
Data rate, each lane   53.125   Gbps
Signaling speed accuracy -100   100 ppm
Wavelengths 1 844   863 nm
Wavelengths 2 900   918 nm
Average receive power -8.2   +4 dBm
Optical modulation amplitude receive -   +3 dBm
Damage threshold +5     dBm
Saturation power 3.5     dBm
Receiver reflectance     -12 dB
Receiver sensitivity Max (-6.6, SECQ - 8) @5E-5 dBm
Stress sensitivity OMA     -3.5 dBm
Conditions of stressed receiver sensitivity test
Stressed eye closure for PAM4 (SECQ)   4.5   dB
OMAouter of each aggressor lane   +3   dBm
No-power monitor RX   -40   dBm
LOS assert (OMA) -30     dBm
LOS de-assert (OMA)     -5.9 dBm
LOS hysteresis 0.5     dBm
Electrical Characteristics
Parameter Symbol Min Typ Max Unit
Power dissipation       4 W
Supply current Icc     1.276 A
Transmitter
Differential input voltage swing Vpp 35   900 mV
Differential input impedance Zin 90 100 110 Ω
Receiver
Differential output voltage swing Vpp     900 mV
Differential input impedance Zout 90 100 110 Ω
EEPROM (A0h) Definitions
Lower Page 00h Memory Map
Data Address Name Description Value (Hex) Read/Write
0 Identifier Identifier   Read-Only
1 Status Revision Compliance   Read-Only
2 Status   Read-Only
3 Interrupt Flags L-Tx/RX LOS, channel 1~4   Read-Only
4 L-Tx/RX Adapt EQ Fault, channel 1~4 L-TX Fault, channel 1~4   Read-Only
5 L-Tx/RX LOL, channel 1~4   Read-Only
6 L-Temp High/Low Alarm/Warning Initialization complete flag   Read-Only
7 L-VCC High/Low Alarm/Warning   Read-Only
8 Vendor Specific   Read-Only
9 L-Rx Power High/Low Alarm/Warning, channel 1~2   Read-Only
10 L-RxPower High/Low Alarm/Warning, channel 3~4   Read-Only
11 L-Tx Bias High/Low Alarm/Warning, channel 1~2   Read-Only
12 L-Tx Bias High/Low Alarm/Warning, channel 3~4   Read-Only
13 L-Tx Power High/Low Alarm/Warning, channel 1~2   Read-Only
14 L-Tx Power High/Low Alarm/Warning, channel 3~4   Read-Only
15-18 Reserved   Read-Only
19-21 Vendor Specific   Read-Only
22 Free Side Device Monitors Internally measured temperature (MSB)   Read-Only
23 Internally measured temperature (LSB)   Read-Only
24 Reserved   Read-Only
25   Read-Only
26 Internally measured supply voltage (MSB)   Read-Only
27 Internally measured supply voltage (LSB)   Read-Only
28-29 Reserved   Read-Only
30-33 Vendor Specific   Read-Only
34 Channel Monitors Internally measured RX input power, channel 1 (MSB)   Read-Only
35 Internally measured RX input power, channel 1 (LSB)   Read-Only
36 Channel Monitors Internally measured RX input power, channel 2 (MSB)   Read-Only
37 Internally measured RX input power, channel 2 (LSB)   Read-Only
38 Internally measured RX input power, channel 3 (MSB)   Read-Only
39 Internally measured RX input power, channel 3 (LSB)   Read-Only
40 Internally measured RX input power, channel 4 (MSB)   Read-Only
41 Internally measured RX input power, channel 4 (LSB)   Read-Only
42 Internally measured TX bias, channel 1 (MSB)   Read-Only
43 Internally measured TX bias, channel 1 (LSB)   Read-Only
44 Internally measured TX bias, channel 2 (MSB)   Read-Only
45 Internally measured TX bias, channel 2 (LSB)   Read-Only
46 Internally measured TX bias, channel 3 (MSB)   Read-Only
47 Internally measured TX bias, channel 3 (LSB)   Read-Only
48 Internally measured TX bias, channel 4 (MSB)   Read-Only
49 Internally measured TX bias, channel 4 (LSB)   Read-Only
50 Internally measured TX Power, channel 1 (MSB)   Read-Only
51 Internally measured TX Power, channel 1 (LSB)   Read-Only
52 Internally measured TX Power, channel 2 (MSB)   Read-Only
53 Internally measured TX Power, channel 2 (LSB)   Read-Only
54 Internally measured TX Power, channel 3 (MSB)   Read-Only
55 Internally measured TX Power, channel 3 (LSB)   Read-Only
56 Channel Monitors Internally measured TX Power, channel 4 (MSB)   Read-Only
57 Internally measured TX Power, channel 4 (LSB)   Read-Only
58-73 Reserved channel monitor   Read-Only
74-81 Vendor Specific   Read-Only
82-85 Reserved     Read-Only
86 Control Tx Disable, channel 1~4   Read/Write
87 Rx_Rate_select, channel 1~4   Read/Write
88 Tx_Rate_select, channel 1~4   Read/Write
89 Rx4_Application_Select, Rx Channel 4   Read/Write
90 Rx3_Application_Select, Rx Channel 3   Read/Write
91 Rx2_Application_Select, Rx Channel 2   Read/Write
92 Rx1_Application_Select, Rx Channel 1   Read/Write
93 Reserved High Power Class Enable Power set Power override   Read/Write
94 Tx4_Application_Select, Rx Channel 4   Read/Write
95 Tx3_Application_Select, Rx Channel 3   Read/Write
96 Tx2_Application_Select, Rx Channel 2   Read/Write
97 Tx1_Application_Select, Rx Channel 1   Read/Write
98 Tx/Rx_CDR_control, channel 1~4   Read/Write
99 Reserved   Read/Write
100 Module and Channel Masks Masking Bit for TX/RX LOS indicator, channel 1~4   Read/Write
101 Masking Bit for TX, Adaptive EQ fault indicator, channel 1~4 Masking Bit for TX Transmitter/Laser indicator, channel 1~4   Read/Write
102 Masking Bit for TX/RX CDR Loss of Lock indicator, channel 1~4   Read/Write
103 Masking Bit for Temperature alarm/warning   Read/Write
104 Masking Bit for Vcc alarm/warning   Read/Write
105-106 Vendor Specific   Read/Write
107 Reserved Max Power Consumption   Read/Write
108 Free Side Device Properties Propagation Delay MSB   Read-Only
109 Propagation Delay LSB   Read-Only
110 Free Side Device Properties Advanced Low Power Mode Far Side Managed Min Operating Voltage   Read-Only
111 Assigned for use by PCI Express   Read-Only
112   Read/Write
113 Free Side Device Properties Far-End Implementation
Near-End Implementation
  Read/Write
114 Tx_TurnOn MaxDuration
DatapathInit MaxDuration
   
115 ModSelL wait time exponent
ModSelL wait time mantissa
   
116 Secondary Extended Spec Compliance    
117-118 Reserved      
119-122 Password Change Entry Area     Read/Write
123-126 Password Entry Area     Read/Write
127 Page Select Byte Page Select   Read/Write
128 Identifier Identifier Type of serial Module   Read-Only
129 Ext. Identifier Extended Identifier of Serial Module   Read-Only
130 Connector Code for connector type   Read-Only
131-138 Specification compliance Code for electronic compatibility or optical compatibility   Read-Only
139 Encoding Code for serial encoding algorithm   Read-Only
140 BR, nominal Nominal bit rate, units of 100 MBits/s   Read-Only
141 Extended Rate Select Compliance Tags for extended rate select compliance   Read-Only
142 Length (SMF) Link length supported for SMF fiber in km (note 1)   Read-Only
143 Length (OM3 50 μm) Link length supported for EBW 50/125 μm fiber (OM3), units of 2 m   Read-Only
144 Length (OM2 50 μm) Link length supported for 50/125 μm fiber (OM2), units of 1 m   Read-Only
145 Length (OM1 62.5 μm) Link length supported for 62.5/125 μm fiber (OM1), units of 1 m   Read-Only
146 Length (Copper) Link length of copper or active cable, units of 1 m, Link length supported for 50/125 μm fiber (OM4), units of 2 m   Read-Only
147 Device technology Device technology   Read-Only
148-163 Vendor name QSFP28 vendor name (ASCII)   Read-Only
164 Extended Module Extended Module codes for InfiniBand   Read-Only
165-167 Vendor OUI QSFP28 vendor IEEE company ID   Read-Only
168-183 Vendor PN Part number provided by QSFP28 vendor (ASCII)   Read-Only
184 Vendor rev Revision level for part number provided by vendor (ASCII)   Read-Only
185   Read-Only
186 Wave length or Copper cable Attenuation Nominal laser wavelength (wavelength=value/20 in nm) or copper cable attenuation in dB at 2.5 GHz (Byte 186) and 5.0 GHz (Byte 187)   Read-Only
187   Read-Only
188 Wavelength tolerance Guaranteed range of laser wavelength (+/- value) from nominal wavelength. (wavelength Tol.=value/200 in nm)   Read-Only
189   Read-Only
190 Max case temp. Maximum case temperature in degrees C   Read-Only
191 CC_BASE Check code for base ID fields (Bytes 128-190)   Read-Only
192 Link codes Extended Specification Compliance Codes   Read-Only
193 Options Rate Select, TX Disable, TX Fault, LOS, Warning indicators for: Temperature, VCC, RX power, TX Bias   Read-Only
194   Read-Only
195   Read-Only
196-211 Vendor SN Serial number provided by vendor (ASCII)   Read-Only
212-219 Date Code Vendor's manufacturing date code   Read-Only
220 Diagnostic Monitoring Type Indicates which types of diagnostic monitoring are implemented (if any) in the Module. Bit 1,0 Reserved * Read-Only
221 Enhanced Options Indicates which optional enhanced features are implemented in the Module. * Read-Only
222 BR, nominal Nominal bit rate per channel, units of 250 Mbps. Complements Byte 140 * Read-Only
223 CC_EXT Check code for the Extended ID Fields (Bytes 192-222) * Read-Only
224-255 Vendor Specific EEPROM Vendor Specific ID * Read-Only
Notes: *Represent that the values read from register varied according to module state.


Digital Diagnostics Functions
Digital diagnostic management interface (DDMI) is realized by I2C interface in compliance with SFF-8636. Diagnostic management functions are realized, and the data addresses are listed in the form below.
Performance Item Data Address Monitor Error
Alarm & Warning Monitor
Module temperature 6 22-23 ≤ ±3°C
Module voltage 7 26-27 ≤ ±3%
Bias current 11-12 42-49 ≤ ±10%
Transmitter optical power 13-14 50-57 ≤ ±3 dB
Receiver optical power 9-10 34-41 ≤ ±3 dB
Regulatory Compliance
Feature Category Standard Performance
Safety NRTL UL 62368-1
CAN/CSA C22.2 No. 62368-1
NRTL recognized component for US and CAN
TUV EN 62368-1
EN 60825-1:2014+A11:2021
EN 60825-2
TUV certificate
FDA U.S. 21 CFR 1040.10 & 1040.11, Notice 56 FDA/CDRH certified with accession number according to Laser Notice 56
Electromagnetic Compatibility Radiated
emissions
EN 55032
CISPR 32
ICES-003
VCCI-CISPR 32
AS/NZS CISPR 32
Class B digital device with a minimum -6 dB margin to the limit when tested with a metal enclosure. Final margin may vary depending on system application, good system EMI design practice, ie: suitable metal enclosure and well-bonding, is required to achieve Class B margins at the system level. Tested frequency range: 30 MHz to 40 GHz or 5th harmonic (5 times the highest frequency), whichever is less.
ESD EN 55035
CISPR 35
Withstands discharges of ± 8 kV contact, ±15 kV air.
Radiated
immunity
EN 55035
CISPR 35
Field strength of 10 V/m from 80 MHz to 6 GHz.
Restriction of Hazardous Substances RoHS EN IEC 63000:2018 & BS EN IEC 63000:2018  
ESD Design
Normal ESD precautions are required during the handling of this module. This transceiver is shipped in ESD protective packaging. It should be removed from the packaging and otherwise handled in an ESD protected environment utilizing standard grounded benches, floor mats, and wrist straps.
Parameter Threshold value Notes
ESD of high-speed pins 1 kV Human body model
ESD of low-speed pins 2 kV Human body model
Air discharge during operation 15 kV  
Direct contact discharges to the case 8 kV  
Safety Specification Design
Do not look into fiber end faces without eye protection using an optical meter (such as magnifier and microscope) within 100 mm, unless you ensure that the laser output is disabled. When operating an optical meter, observe the operation requirements.
CAUTION: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.

Qsfp28 100g Bidi Transceiver Module for 70 M/100m Om3/Om4 mm FiberQsfp28 100g Bidi Transceiver Module for 70 M/100m Om3/Om4 mm Fiber
Qsfp28 100g Bidi Transceiver Module for 70 M/100m Om3/Om4 mm Fiber
Qsfp28 100g Bidi Transceiver Module for 70 M/100m Om3/Om4 mm FiberQsfp28 100g Bidi Transceiver Module for 70 M/100m Om3/Om4 mm Fiber

    Send your message to this supplier

    *From:
    *To:
    *Message:

    Enter between 20 to 4,000 characters.

    This is not what you are looking for? Post a Sourcing Request Now
    Contact Supplier